TEMPERATURE MEASUREMENT LABORATORY (Technical Division 10)

General introduction

Temperature Measurement Laboratory (Technical Division 10) belongs to Quality Assurance and Testing Centre 2 (QUATEST 2).
The Lab is the secondary standard laboratory in the field of temperature according to Viet Nam testing measurement calibration Scheme.
The Lab has applied the quality system according to ISO/IEC 17025 standard and has been accredited by BoA, Lab Code is VILAS 024.
The Lab has the functions and missions to perform the measurement of temperature measuring instruments according to Viet Nam testing measurement calibration Scheme, with the following specific services:
• To verify, calibrate and test temperature measuring instruments.
• To repair, adjust and maintain temperature measuring instruments.
• To provide consultancy services on installation and operating instructions for temperature measuring instruments.
• To provide training courses on calibration, verification of temperature instruments.

Standards (Click To See More)
` Names Specification Uncertainty Type Traceability
Standard Platinum Resistance Thermometer – 909H – ISOTECH/UK  

Range: (-40~670) ᵒC

 

U=0,006 °C

Secondary Standard  

VMI

True Temperature Indicator – TTI2 – ISOTECH/UK Range: (0 ~ 440) Ω /(-200 ~ 850) ᵒC; Resolution: 0,1 m Ω; 0,001 ᵒC U=10 ppm Secondary Standard VMI
Standard Thermocouple type S – E125-S – ISOTECH/UK Range: (0~1450) ᵒC U=(1,0~2,5)°C Secondary Standard VMI
Multichannel Thermometer – 4312B-14-07 – INSTRULAB Range: (-45~300) ᵒC; Resolution: 0,001  ᵒC U=(0,10~0,16)°C Working Standard QUATEST 2
Multichannel Thermometer – 740 – KEITHLEY Range: (50~1200) ᵒC; Resolution: 0,1  ᵒC U=(0,22~1,87)°C Working Standard QUATEST 2
Wireless thermometer – DISKINTERFACE HS Range:(0~140) ᵒC;

Error: ± 0,1 ᵒC

U=0,1°C Working Standard QUATEST 2
Multi calibrator – 5520A – FLUKE USA Range: (-200 ~ 1800) ᵒC U=(0,05~0,46 °C Secondary Standard QUATEST 2
Reference multi meter – 8508A – FLUKE USA Range:

– mV (DC): (0 ~ 200) mV;

– Ohm: (0 ~ 1) kΩ;

– mA (DC): (4 ~ 20) mA

 

U=13 ppm

 

Secondary Standard

 

VMI

Dry – well and Liquid Bath Range: (-200 ~ 1800) ᵒC; U=(0,07~1,8) °C Working Standard VMI
Black Body – 9132 – FLUKE USA Range: (50 ~ 500) ᵒC; U=0,29°C National Standard
QUATEST 2
Temperature measuring instruments/Test properties (Click To See More)
STT Temperature measuring instruments Procedures
I. Verification:
1 Liquid-in-glass thermometers ĐLVN 20: 2009
2 Mercury-in-glass thermometers with Maximum structure ĐLVN 159: 2005
3 Mercury-in-medical glass thermometers with Maximum structure ĐLVN 21: 2009
4 Electronic medical thermometers with Maximum Structure ĐLVN 23 : 1998
II. Calibration:
1 Liquid-in-glass thermometers ĐLVN 137 : 2004
2 Digital & analog thermometers, Digital & analog Self -recording thermometers, Infrared Thermometers, Digital & analog temperature indicators. ĐLVN 160: 2005

ĐLVN 138: 2004

ĐLVN 124: 2003

 

3 Industrial platinum resistance thermometers, Industrial thermocouples ĐLVN 125: 2003

ĐLVN 161:2005

ĐLVN 123:2003

4 Temperature transmitters QTHC/TT2
5 Thermal chambers (Drying Oven, Heated Cabinets, Refrigerator…) QTHC/TT2
6 Liquid Bath QTHC/TT2
7 Furnace QTHC/TT2
8 Autoclaves QTHC/TT2
9 Dry – Well QTHC/TT2

 


For more information please contact